Menu Close

MH Series Horizontal Multistage

The MH Series, multistage booster pump is designed to meet your pressure boosting needs. The stainless steel construction offers high performance in a wide variety of applications.

  • Flow:
  • up to 29 m³/h (MH) at 50 Hz
  • up to 30 m³/h at 60 Hz
  • Head:
  • up to 104 m at 50 Hz
  • up to 111 m at 60 Hz
  • Connections: Rp threaded for inlet and outlet
  • Maximum working pressure: 10 Bar
Contact us for more info

 

Category:

The MH Series, multistage booster pump is designed to meet your pressure boosting needs. The stainless steel construction offers high performance in a wide variety of applications. The MH Series is available in five flow rates and different horsepower sizes in 1-phase or 3-phase to make sure you have the right pump to fit your application.

  • Features

    • Compact close-coupled design, robust and corrosion resistant
    • Superior efficiency and performance
    • Flexible application base plate
    • Floating neck ring in PPS
    • Heavy duty oversize motor shaft
    • Impellers and diffusers are made of stainless steel in order to achieve durability
    • Easy maintenance
    • Strong and leak-proof motor ball bearing fitted in the motor
    • Pumping of clear non-loaded fluids
    • Mechanical seal Type E0 = carbon/ceramic/EPDM: 3-5-9 MH
    • Mechanical seal Type E1 = carbon/silicon carbide/EPDM: 15-20 MH

    Pump Specifications

    • Flow:
    • up to 29 m³/h (MH) at 50 Hz
    • up to 30 m³/h at 60 Hz
    • Head:
    • up to 104 m at 50 Hz
    • up to 111 m at 60 Hz
    • Connections: Rp threaded for inlet and outlet
    • Maximum working pressure: 10 Bar
    • Maximum allowable amount of sand: 50 g/m³
    • Maximum ambient temperature: 40 °C
    • Liquid temperature range:
    • Minimum: from -15 °C to -10 °C according to gasket material
    • Maximum: +90 °C for domestic use (uses covered by CEI EN standard 60335-2-41); +110 °C only for industrial use (uses other than those covered by CEI EN standard 60335-2-41)
    • The hydraulic characteristics are guaranteed, according to ISO standard 9906:2012, grade 3B

    Motor Specifications

    • Single-phase
    • Three-phase motor efficiency class IE3
    • Asynchronous, TEFC (Totally Enclosed, Fan-Cooled)
    • 2 pole
    • Protection IP55, insulation class F
    • Standard voltage:
    • Single-phase:
    • 220-240 V ±5 % (Thermal protection built into the motor)
    • Three-phase:
    • 220-240 V / 380-415 V ±5 % up to 3 kW (Thermal protection to be provided into the starter panel by the installer)
    • 380-415 V / 660-690 V ±5 % from 4 kW (Thermal protection to be provided into the starter panel by the installer)
    • Frequency of starts:
    • Max. 60 starts/hour for motor power up to 3 kW (with min. 1 minute resting time)
    • Max. 30 starts/hour for motor power from 4 kW (with min. 2 minute resting time)

    Available on request

    • Special mechanical seal
    • Discharge inlet/outlet NPT

50Hz Performance

60Hz Performance